4
2. FEATURE DESCRIPTIONS
2.1. START COMMANDS
There is a total of 6 START inputs available. Each START
COMMAND requires a momentary (250 ms minimum)
contact closure for the program to recognize the
command. The commands will be stored in a first-in, first-
out(FIFO) manner. Multiple closures, after the first
recognition of the command, will be executed in order as
they were recognized by FIFO after the completion of the
first command. If the command is "latched" ON the
message will repeat until the contact closure is removed.
2.2. STOP/RESET COMMAND
A momentary (250 ms minimum) contact stops
(terminates) the message that is playing. All messages in
FIFO will be aborted. All active inputs have to be
reactivated for normal operation. (See SUPERVISION for
additional use.)
2.3. TEST COMMAND
When TEST COMMAND is maintained for at least 250 ms
before the START #1 COMMAND is provided, the built-in
test message is played. The TEST COMMAND must be
maintained until the playing cycle is complete or the
ERROR/FAIL relay will indicate a malfunction. Thus, the
TEST feature may be used to play the built-in test
message for a check of the entire public address system
or to TEST the unit's ERROR/FAIL function.
2.4. BUILT-IN TEST MESSAGE
The TEST MESSAGE is stored within the program
EPROM which is a basic part of the PD-006 board
circuitry.
The test message says, "This is an audio system test".
Comentarios a estos manuales